Evolve EVBF Guía para resolver problemas

Busca en linea o descarga Guía para resolver problemas para Dispensador De Agua Evolve EVBF. Evolve EVBF Troubleshooting guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Evolve Series

Evolve Series® Water FiltersFor Models:• EVFE• EVS• EAG• EACG• EVBF• EVBF-AN

Pagina 2 - TABLE OF CONTENTS

10 START-UP INSTRUCTIONS:FLUSHING OF SYSTEM:To flush the system of any debris and air after installation is complete, please perform the following ste

Pagina 3

11 OPERATING DISPLAYS AND INSTRUCTIONS:The air sulfur and air iron filter systems look and function much like any backwashing whole house filter; howe

Pagina 4 - BYPASS VALVE:

4. MANUAL REGENERATION: Sometimes there is a need to regenerate before the control valve calls for it. This may be needed if a period of heavy water

Pagina 5 - INSTALLATION:

131. Check the media height by shining a flashlight through the tank to see the height of the mineral. If the level is not seen, the top fill plug wi

Pagina 6 - (Air charge

14 PROBLEM CAUSE CORRECTION 1. No display on PC board A. No power at electric outlet A. Repair outlet or use working outlet B. Control valve pow

Pagina 7 - ASSEMBLY

15 7. Control valve does not regenerate automatically but does when the correct button(s) is depressed and held. For timeclock valves the buttons ar

Pagina 8 - PROGRAMMING PROCEDURES:

TROUBLESHOOTING GUIDE cont’d:16 12. Control valve fails to draw in regenerant A. Injector is plugged A. Remove injector and clean or replace B. F

Pagina 9

17 PROBLEM CAUSE CORRECTION 15. E2, Err – 1002, Err – 102 = Control valve motor ran too short and was unable to find the next cycle position and

Pagina 10 - START-UP INSTRUCTIONS:

18 PROBLEM CAUSE CORRECTION 19. Err – 1007, Err – 107, Err - 117 = MAV/ SEPS/NHBP/AUX MAV valve motor ran too short (stalled) while looking for

Pagina 11 - DEALER NA

REPLACEMENT PARTS:2713546FRONT COVER AND DRIVE ASSEMBLYItem No. Part No. Description Qty.1CV3367-01-A Black cover 1CV3367-01-WR-A Gray cover 12 CV31

Pagina 12 - BATTERY REPLACEMENT

TABLE OF CONTENTSPreinstallation Instructions for Dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Bypass Valve . . . . .

Pagina 13 - FOR ACID NEUTRALIZERS:

2023458677911314101112NOTE: Not available on 1¼ " valve.REPLACEMENT PARTS:PISTON ASSEMBLYItem No. Part No. Description Qty.1CV3005 1”

Pagina 14 - TROUBLESHOOTING GUIDE:

REPLACEMENT PARTS:BYPASS VALVE Item No. Part No. Description Qty.1 CV3151 Nut, 1” quick connect 22 CV3150 Split ring 23 CV3105 O-ring 215 24 CV3145

Pagina 15 - PROBLEM CAUSE CORRECTION

22INJECTOR ASSEMBLIESItem No. Part No. Description Qty.1 CV3176 Injector cap 12 CV3152 O-ring 135 13 CV3177-01 Injector screen 14 CV3010-1Z Inject

Pagina 16 - TROUBLESHOOTING GUIDE cont’d:

DRAIN LINE ASSEMBLY 3/4”Item No. Part No. Description Qty.1 CH4615 Elbow locking clip 12 CPKP10TS8-BULK Optional insert, 5/8” tube 13 CV3192 Option

Pagina 17

WATER METER & METER PLUGItem No. Part No. Description Qty.1 CV3151 Nut, 1” QC 12 CV3003 Meter assembly, includes items 3 & 4 13 CV3118-01

Pagina 18

REPLACEMENT PARTS:25CHLORINE TANK ASSEMBLYItem No. Part No. Description Qty.1 CH4600-50 474 safety float valve 12 CH4640-32 474 float assembly 13 CH

Pagina 19 - REPLACEMENT PARTS:

1” PVC MALE NPT ELBOWItem No.Part No. Description Qty.CV3007 1” PVC male NPT elbow assembly 21 CV3151 Nut, 1” quick connect 22 CV3150 Split ring 23

Pagina 20

271-1/4” & 1-1/2” PVC SOLVENTItem No.Part No. Description Qty.CV3007-07 1-1/4” & 1-1/2” PVC solvent assembly 21 CV3151 Nut, 1” quick connect

Pagina 21

28 SPECIFICATIONS:SULFUR AND IRON AIR FILTERSMineral Type Catalytic Carbon Catalytic Carbon Catalytic Carbon Birm Birm BirmAmount (Cu Ft) 1.0 1

Pagina 22

29ACID NEUTRALIZERSBACKWASHING FILTERSMineral Type Calcite or Mix Calcite or Mix Calcite or Mix Calcite or Mix Calcite or Mix Calcite or MixAmou

Pagina 23

PREINSTALLATION INSTRUCTIONS FOR DEALERS:3The manufacturer has preset the water treatment unit’s sequence of cycles and cycle times.The dealer should

Pagina 24

Evolve Series® Water Conditioner Limited WarrantyCongratulations. You have purchased one of the  nest water treatment systems available. In the unlik

Pagina 25

31MANUAL REGENERATIONNOTE: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regeneration. If you

Pagina 26

Manufactured exclusively for Evolve Series Dealers at:1900 Prospect Court • Appleton, WI 54914Phone: 920-739-9401 • Fax: 920-739-9406© 2014 Evolve

Pagina 27

4The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs o

Pagina 28 - SPECIFICATIONS:

5GENERAL INSTALLATION & SERVICE WARNINGSThe control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There

Pagina 29

6 When installing an air regenerating filter the customer may experience, under certain conditions, small amounts of air (cloudy water) at the tap

Pagina 30

78. CHECK VALVE: All air systems include an internal check valve and screen assembly as part of the air draw system (see diagram at right). This chec

Pagina 31 - QUICK REFERENCE GUIDE:

81. Set time of day: PROGRAMMING PROCEDURES:NOTE: The manufacturer has preset the unit so that the gallons between regenerations will be automaticall

Pagina 32 - LIGHT NORMALLY

9 NOTE: This valve has the capability of regenerating up to six times in one day. This can be observed by pressing the CLOCK and + buttons sim

Comentarios a estos manuales