MANUAL REGENERATION
NOTE: For softeners, if
brine tank does not contain
salt, fill with salt and wait
at least two hours before
regeneration. If you need
to initiate a manual regeneration, either
immediately, or the same night at the
preprogrammed time for regeneration (typically 2:00 AM),
complete the following steps.
For Immediate Regeneration:
Press and hold
REGEN until valve motor starts (typically 5 seconds).
For Regeneration the same night:
Press and release
REGEN (notice that flashing “REGEN TODAY” appears).
ERROR
If the display toggles between “Error”
and an error code (i.e. a number),
call a service technician and report
the error code.
BYPASS VALVE OPERATION
To shut off water to the system, position arrow handles as shown in
the bypass operation diagram below. If your valve doesn’t look like
the diagram below, contact your service technician for instructions
on how to shut off water.
NORMAL OPERATION BYPASS OPERATION
ADJUST HARDNESS, DAYS BETWEEN REGENERATION,
OR TIME OF REGENERATION
For initial set-up or to make adjustments,
please complete the steps as shown to
the right. Access this mode by pressing
NEXT and + button simultaneously.
NOTE: Hardness display shows “-nA-”
if used as a filter. If other displays do
not appear, refer to manual.
GENERAL OPERATION
When the system is operating, one of three displays will be shown:
time of day, gallons of treated water available, or gallons per
minute. Pressing
NEXT will toggle between the three choices.
TO SET TIME OF DAY
In the event of a prolonged power outage,
time of day flashes, indicating that this
needs to be reset. All other information will
be stored in memory no matter how long
the power outage. Please complete the
steps as shown to the right. To access this
mode, press
CLOCK.
1. Accessed by pressing
CLOCK
2. Adjust hours with + and — buttons,
AM/PM toggles at 12
3. Press NEXT
4. Adjust minutes with + and — buttons
5. Press
NEXT to complete and return to
normal operation
1. Accessed by pressing
NEXT and +
button simultaneously
2. Adjust hardness using + and — buttons
3. Press NEXT
4. Adjust days between regenerations
using + and — buttons
5. Press NEXT
6. Adjust time of regeneration hour with +
and — buttons, AM/PM toggles at 12
7. Press NEXT
8. Adjust time of regeneration minutes
with + and — buttons
9. Adjust backlight setting with + and
— buttons
10. Press
NEXT to complete and return
to normal operation